Description
DPO4PWR Power Analysis Application Module
Enables quick and accurate analysis of power quality, switching loss, harmonics, safe operating area (SOA), modulation, ripple, and slew rate (dI/dt, dV/dt).
Recommended Probing - Differential Voltage; Current
MEASUREMENTS
Power quality measurements
- VRMS, VCrest Factor, Frequency, IRMS, ICrest Factor, True Power, Apparent Power, Reactive Power, Power Factor, Phase Angle
Switching loss measurements
- Power loss
- TOn, TOff, Conduction, Total
- Energy loss
- TOn, TOff, Conduction, Total
Harmonics
- THD-F, THD-R, RMS measurements up to 400 harmonics
- Graphical and table displays of harmonics
- Test to IEC61000-3-2 Class A and MIL-STD-1399 Section 300 A
Ripple measurements
- VRipple and IRipple
Modulation analysis
- Graphical display of +Pulse Width, –Pulse Width, Period, Frequency, +Duty Cycle, and –Duty Cycle modulation types
Safe operating area
- Graphical display and mask testing of switching device safe operating area measurements
dV/dt and dI/dt measurements
- Cursor measurements of slew rate
DESKEW
Recommended deskew values automatically calculated based on propagation delay. Deskews can be set to recommended values or adjusted manually.