Chroma 87001 Series
CHR-87001
CHR-87001
Chroma Digitale Power meter 66200 series
RAD-RPR3006W
RAD-CPL
RAD-RGN2400A
The range of RadiGen EMC/RF signal generator plug-in cards are intended to be used in the RadiCentre (Pro) modular EMC test systems and are available in two models. The RGN2400A covers a frequency range from 9 kHz to 400 MHz and is mainly intended for conducted immunity test applications, like IEC61000-4-6, Mil.Std.461 CS-114 (BCI) or Automotive ISO11452-4 (BCI). The model RGN2006B covers a frequency range from 4 kHz to 6 GHz and can additionally be used for radiated immunity test applications, like IEC61000-4-3. The generator provides carrier signals from -70 dBm to +13 dBm with a frequency accuracy of +/- 1 ppm and supports different modulation types, like AM, FM and (Gated), Pulse modulation. The internal 10 MHz reference can be used as external reference source for other instrumentation.
RAD-RGN2006B
The range of RadiGen EMC/RF signal generator plug-in cards are intended to be used in the RadiCentre (Pro) modular EMC test systems and are available in two models. The RGN2400A covers a frequency range from 9 kHz to 400 MHz and is mainly intended for conducted immunity test applications, like IEC61000-4-6, Mil.Std.461 CS-114 (BCI) or Automotive ISO11452-4 (BCI). The model RGN2006B covers a frequency range from 4 kHz to 6 GHz and can additionally be used for radiated immunity test applications, like IEC61000-4-3. The generator provides carrier signals from -70 dBm to +13 dBm with a frequency accuracy of +/- 1 ppm and supports different modulation types, like AM, FM and (Gated), Pulse modulation. The internal 10 MHz reference can be used as external reference source for other instrumentation.
PEN-SCN-522/3G
PEN-SCN-522/6G
PEN-SCN-524/3G
PEN-SCN-524/6G
PEN-SCN-534/3G
PEN-SCN-534/6G
PEN-SCN-564/3G
PEN-SCN-564/6G
KIK-TOS5302
HAE-2499980
HAE-2499982
KIK-TOS5300
KIK-TOS5301
EME Guard XS
80-6 000 MHz
The EME Guard XS is an EMF measuring device to alert workers near antennas. It continously scans for electromagnetic waves and, via its built-in alarm and visual system, alerts users whenever the acceptable limits have been exceeded. This RF Safety tool is extremely easy to use and creates a safer working environment in the areas of installation and maintenance.
HAE-Axos 8
RAD-RSS2010B
RAD-RSS2010H
RAD-RSS2010I
RAD-RSS2010S
Chroma 61502
RAD- RSW1021B
EMC and RF test setups often consist of many signal paths. In order to enable automated testing, it should be possible to switch these signal paths in an automated manner. The series of RadiSwitch® plug-in cards in combination with a RadiCentre® test system do just that.
RAD- RSW1022K
EMC and RF test setups often consist of many signal paths. In order to enable automated testing, it should be possible to switch these signal paths in an automated manner. The series of RadiSwitch® plug-in cards in combination with a RadiCentre® test system do just that.
RAD- RSW1062K
EMC and RF test setups often consist of many signal paths. In order to enable automated testing, it should be possible to switch these signal paths in an automated manner. The series of RadiSwitch® plug-in cards in combination with a RadiCentre® test system do just that.
RAD-RSW1024S
EMC and RF test setups often consist of many signal paths. In order to enable automated testing, it should be possible to switch these signal paths in an automated manner. The series of RadiSwitch® plug-in cards in combination with a RadiCentre® test system do just that.
HAE-Axos 5
NAR-Nardalert S3
CHR-66201
CHR-66202
EME Guard
27-40 000 MHz
EME Guard is a broadband rf safety dosimeter that continuously measures electromagnetic fields and alerts the user when pre-set thresholds are exceeded.