Toggle Nav
Products

MPI

Set Descending Direction
TS2000-SE
TS2000-SE
MPI-TS2000-SE

200mm Shielded Automated Probe Station

TS150-HP
TS150-HP
MPI-TS150-HP

150mm Manual High Power System

TS200-HP
TS200-HP
MPI-TS200-HP

200mm Manual High Power System

TS150
TS150
MPI-TS150

150mm Standard Manual System

TS200
TS200
MPI-TS200

200mm Standard Manual System

TS300
TS300
MPI-TS300

300mm Standard Manual System

TS150-THZ
TS150-THZ
MPI-TS150-THZ

150mm Manual System for mmW and THz Application

TS200-THZ
TS200-THZ
MPI-TS200-THZ

200mm Manual System for mmW and THz Application

TS200-SE
TS200-SE
MPI-TS200-SE

200mm Shielded Manual System

TS300-SE
TS300-SE
MPI-TS300-SE

300mm Shielded Manual System

TS300-PCB
TS300-PCB
MPI-TS300-PCB

Large Wafer and PCB testing

TS600-PCB
TS600-PCB
MPI-TS600-PCB

Large Wafer and PCB testing for Accurate and Reliable RF and mmW Measurements on PCB Boards

TS2000
TS2000
MPI-TS2000

200mm Automated Probe Station

TS2000-HP
TS2000-HP
MPI-TS2000-HP

Advanced 200mm Automated High Power Solution 

TS2000-IFE
TS2000-IFE
MPI-TS2000-IFE

MPI's Most Versatile 200 mm Platform

TS2500
TS2500
MPI-TS2500

200mm Fully-Automatic Probe Systems for 24/7 Production Tests

TS3000-HP
TS3000-HP
MPI-TS3000-HP

Advanced 300 mm High Power Solutions

TS3000-IFE
TS3000-IFE
MPI-TS3000-IFE

MPI's Most Versatile 200 mm Platform

TS3000-SE
TS3000-SE
MPI-TS3000-SE

300 mm Automated Probe System with ShielDEnvironment™

TS3500-HP
TS3500-HP
MPI-TS3500-HP

Advanced 300 mm High Power Solutions

TS3500-SE
TS3500-SE
MPI-TS3500-SE

TS3500 Series with WaferWallet® = Accuracy + Flexibility + Automation

SiPho
SiPho
MPI-SiPho

MPI Designed Dedicated SiPH Upgrades for its well-known 200 and 300 mm Probe Systems

ITS25-THZ
ITS25-THZ
MPI-ITS25-THZ

ITS25-THZ IMPACT™ Test Solution, enables cost effective mmW and THZ testing with the highest possible measurement accuracy

• ITS25-THZ is equipped with dedicated mmW chuck supporting probing of submillimeter-wave MMICs as small as 1 x 1 mm and up to 25 x 25 mm

• The chuck is made completely by ceramics, and supports both the DUT and the calibration standards. Dielectric properties of the chuck material and its design are optimized to suppress possible
propagation of higher-order modes providing accurate system calibration and trustable measurement results at THz frequencies

• The set of MP80 MicroPositioners and unique integration of all types of frequency extenders available on the market is designed for direct wafer probe mount and eliminates the need for additional
waveguide section. This solution guarantees the best possible measurement directivity of the system in the entire measurement frequency range of up to 1.5 THz

• MPI supports ALL available on the market: Frequency Extenders by unique Adaptation (FEAD), for easy reconfiguration and safety operation

ITS50-COAX
ITS50-COAX
MPI-ITS50-COAX

50 mm Manual Probe System for accurate and reliable DC/CV measurements.

ITS50-RF26
ITS50-RF26
MPI-ITS50-RF26

50 mm Manual Probe System for accurate and reliable RF measurements

ITS50-TRIAX
ITS50-TRIAX
MPI-ITS50-TRIAX

50 mm Manual Probe System for accurate and reliable DC/CV measurements.

ITS150-TRIAX
ITS150-TRIAX
MPI-ITS150-TRIAX

150 mm Manual Probe System for accurate and reliable DC/CV measurements.

ITS150-COAX
ITS150-COAX
MPI-ITS150-COAX

150 mm Manual Probe System for accurate and reliable DC/CV measurements.

ITS150-HP
ITS150-HP
MPI-ITS150-HP

150 mm High Power Manual Probe System for accurate High Power measurements up to 10 kV, 600 A

ITS150-RF26
ITS150-RF26
MPI-ITS150-RF26

150 mm Manual Probe System for accurate and reliable RF measurements.

Comes with 26GHz probes, but is upgradable to 40, 50 and 67GHz.

ITS150-RF
ITS150-RF
MPI-ITS150-RF

150 mm Manual Probe System for accurate and reliable RF measurements.

Does not come with RF probes or calibration substrate. Please consider ITS-150-RF26 if you want to have a complete package including probes and calibration substrate.

ITS150-THZ
ITS150-THZ
MPI-ITS150-THZ

Industry‘s first explicitly designed probe system for accurate mmW and THz measurements

T26V-GSXXXX
T26V-GSXXXX
MPI-T26V-GSXXXX

 - DC to 26 GHz RF probe
 - Connector type : SMA 
 - 90 degree connector
 - GS tip configuration 
 - Pitch from 50 µm to 450 µm with 25 µm step 
 - Pitch from 450 µm to 1250 µm with 50 µm step
 - Available  pitches 90 µm
 - Please specify the required pitch during ordering process

€ 460,00
T40A-GS/SG/GSGXXXX
T40A-GS/SG/GSGXXXX
MPI-T40A-GS/SG/GSGXXXX

  - DC to 40 GHz RF probe
 - Connector type : K (2.92 mm)
 - 45 degree connector
 - GSG , GS and SG tip configuration are possible, please chose on order
 - Pitch from 50 µm to 450 µm with 25 µm step 
 - Pitch from 450 µm to 800 µm with 50 µm step
 - Other available pitches: 90 µm 
 - Please specify the required pitch during ordering process

€ 640,00
T26A-GSGXXXX
T26A-GSGXXXX
MPI-T26A-GSGXXXX

 - DC to 26 GHz RF probe
 - Connector type : SMA
 - 45 degree connector
 - GSG tip configuration
 - Pitch from 50 µm to 450 µm with 25 µm step 
 - Pitch from 450 µm to 1250 µm with 50 µm step 
 - Available  pitches 90 µm
 - Please specify the required pitch during ordering process

€ 460,00
T26A-SGXXXX
T26A-SGXXXX
MPI-T26A-SGXXXX

 - DC to 26 GHz RF probe
 - Connector type : SMA
 - 45 degree connector
 - SG tip configuration
 - Pitch from 50 µm to 450 µm with 25 µm step 
 - Pitch from 450 µm to 1250 µm with 50 µm step 
 - Available  pitches 90 µm
 - Please specify the required pitch during ordering process

€ 460,00
Page